24kv 36kv Vacuum Circuit Breaker Recloser

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2020-12-02 06:22

  • Browse the number:

    438

Send an inquiries

Company Profile

Yueqing Tyou Electric Co., Limited

By certification [File Integrity]

Contact:tyouele(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website:http://www.tyouelectric.com/ http://tyouele.men0222.com/

Product details

Specification:

ZW32-12 type outdoor pole-mounted HV vacuum CB (hereinafter referred to as CB) is rated voltage12kV, 50Hz three-phase AC outdoor power distribution equipment used for power distribution network to break and close load current, over-load current and short-circuit current in electric systems. It is used in substation and industrial & mining enterprise power distribution system for protection and control, better fits countryside power grid and frequent operation places, especially for the retrofit of urban power network and countryside power network. Characteristic:
The CB applies three-phase pole-type structure. It has characteristics of stable closing/breaking property, no fire or explosion danger, maintenance-free, small dimension, small weight, long service life, etc.

CBS can be fitted with two-phase or three-phase current transformers for automatic over-current release and supplying circuit information for intelligent controller.
Weight of CB<100kg
Overall dimension: H× W× D 740x960x880 (with isolation) 720x900x240 (without isolation)


Items

Unit

ZW32-12/400

ZW32-12/630

ZW32-12/1250

Rated voltage

kV

12

Rated current

A

400

630

1250

Rated short circuit breaking current

kA

20/25

Rated short circuit making current (peak value)

50

Rated peak withstand current

50

Rated short circuit withstand current

50

Rated short circuit duration

S

4

Rated insulating level

1 minimum PF withstand voltage

Phase to phase, to ground 40, fracture 48

Lightning impolse withstand voltage peak value

phase to phase, to ground 75, fracture 85

Rated sequence of operations


O-0.3s-CO-180s-CO

Rated short circuit current breaking time


30

Mechanical endurance


10,000

Rated operation voltage (opening, closing coil)

V

DC220,110 AC220,110

Moving and fixed contact allowance wearing collation thickness

mm

3

Over-current release nominal current


5

Current transformer ratio

A

200/5,400/5 and 600/5

1 minimum second PF withstand voltage

mm

2

Over current tripping current

A

5

Rated single capacitor bank switching current

kA

630